Abaxis Piccolo xpress™ Point of Care blood chemistry analyzer

By Cruinn Team, Thursday, 9th February 2012 | 0 comments

The Piccolo Xpress is a compact, portable clinical chemistry system designed for on-site patient testing. Roughly the size of a shoebox, health care providers use the easy to follow color touch screen commands to perform routine multi-chemistry panels. 0.1cc of whole blood, serum or plasma is added directly to the patented 8-cm diameter single use plastic disc containing the liquid diluent and dry reagents. The disc is placed in the analyzer drawer where centrifugal and capillary forces are used to mix the reagents and sample in the disc. The Piccolo Xpress monitors the reagent reactions simultaneously using nine wavelengths, calculates the results from the absorbance data and reports the results.

Abaxis Piccolo.JPG abaxis logo.jpeg

The Piccolo Xpress self-calibrates with each run and the on-board continuous intelligent Quality Control (iQCT) monitors the analyzer, reagent reactions and sample to ensure chemistry and instrument integrity. This assures you the highest quality and accuracy in results. Results are ready in approximately 12 minutes with a “hard copy” report suitable for the patient file or transferred to a computer, printer or an LIS/EMR. This enables you to rapidly obtain critical diagnostic information at point of care. The easy-to-use, low maintenance system requires no special training to operate.

Lab Manager, Karen Jurcsak and the staff at New York Oncology Hematology know the importance of state-of-the-art technology in providing quality patient care. Karen writes:

“The Piccolo has made it possible for even our smaller labs to provide quality, cost efficient, and timely chemistry results. In turn, the overall quality of patient care and satisfaction has increased. Piccolo has made the difference. We installed them in five sites and we would not want to be without them.”

For more information please contact us.

 

Cruinn Team

 


 

 

 

Categories


Comment on This Article

HTML is disabled and your e–mail address won't be published. Comments will be deleted if commenters leave a keyword instead of a name in the name field, if sites linked in the URL field are commercial in nature and not related to the blog, or if the comment simply doesn't add substance to the discussion.

Spam Prevention

In order to submit this form successfully, you must complete this question

Please match the colour       blue
Please match the colour

© 2012 Cruinn Diagnostics Limited

  • 5b/6b Hume Centre,  Park West Industrial Estate, Nangor Road, Dublin 12,  Ireland
  • Phone: +353 1 629-7400
  • Fax: +353 1 629-7401
  • Email: info@cruinn.ie

Search

Search - Use spaces to separate your keywords